Hi-MO One Pro

Expand storage capacity independently of power.

Hi-MO One Pro combines 125 or 250 kW power configurations with modular DC battery expansion. One AC master can support up to 11 additional battery cabinets, extending nominal storage duration to approximately 24 hours in the documented 125 kW configuration.

Hi-MO One Pro
125 / 250 kW
Power configurations
3.13 MWh
With 11 expansion cabinets
Up to 24 h
Nominal storage duration
20 ms or less
Switching with the optional STS

What it does for your site.

Expand storage capacity independently of power

The modular AC/DC architecture allows independent expansion of battery capacity.

  • One AC master supports up to 11 additional DC battery cabinets, reaching approximately 3.13 MWh of nominal storage capacity without additional PCS units.
Expand storage capacity independently of power: sketch illustrationAI-generated image

Store electricity for up to 24 hours

The system supports 2-24 hours of nominal storage duration through modular battery expansion in the 125 kW configuration.

  • Each additional DC cabinet contributes 261.24 kWh of storage capacity.
Store electricity for up to 24 hours: sketch illustrationAI-generated image

Match power output to operational demand

The AC cabinet supports 125 kW or 250 kW rated output, depending on whether one or two PCS units are installed.

  • Maximum output power reaches 137.5 kW or 275 kW, respectively.
Match power output to operational demand: sketch illustrationAI-generated image

Connect multiple energy sources

Supports PV, grid and diesel generator integration, including up to 250 kW AC-coupled PV and 400 kVA diesel generator input.

  • Direct PV DC coupling is available as an optional configuration.
Connect multiple energy sources: sketch illustrationAI-generated image

Maintain critical operations during grid outages

Supports grid-connected and off-grid operation.

  • Standard transfer takes approximately 2-3 minutes.
  • An optional Static Transfer Switch (STS) enables ≤20 ms switching in appropriately configured systems.
Maintain critical operations during grid outages: sketch illustrationAI-generated image

Achieve high system efficiency

90.5% system comprehensive efficiency.

  • LONGi-developed PCS, BMS, EMS, and TMS technologies support coordinated system operation.
  • The built-in energy management system coordinates charging and discharging according to operating requirements.
  • It supports peak demand management and energy shifting without requiring a separate EMS installation.
Achieve high system efficiency: sketch illustrationAI-generated image

Detect battery risks before they escalate

LONGi's intelligent Cell Connection System (iCCS) monitors individual battery cells for developing abnormalities.

  • The three-level BMS architecture and automatic fault isolation provide additional safety protection.
Detect battery risks before they escalate: sketch illustrationAI-generated image

Maintain performance across demanding temperatures

Liquid cooling regulates battery temperature.

  • The system operates between −30°C and +55°C, with AC cabinet power derating above 50°C.
Maintain performance across demanding temperatures: sketch illustrationAI-generated image

Expand the system without replacing existing equipment and reduce investment costs

The master-slave architecture supports phased expansion through additional 261.24 kWh DC battery cabinets.

  • Automatic recognition simplifies integration, and existing PCS capacity can be retained, avoiding unnecessary investment in additional power conversion equipment.
Expand the system without replacing existing equipment and reduce investment costs: sketch illustrationAI-generated image

Connect multiple energy sources and storage systems through dedicated combiner cabinets

Optional D5 and D9 combiner cabinets support centralized electrical integration of up to five ESS circuits.

  • The D9 also accommodates PV, grid and diesel generator connections, with rated capacities of 400 kW PV, 1,250 kW grid and 500 kW diesel generation.
Connect multiple energy sources and storage systems through dedicated combiner cabinets: sketch illustrationAI-generated image

Fire safety supported by UL 9540A testing

UL 9540A fire propagation testing supports the assessment of thermal runaway risks. Hi-MO One Pro also features multi-stage fire detection and suppression, supported by its three-level BMS architecture.

Industries and applications

Where Hi-MO One Pro puts storage to work.

  • Industrial manufacturingAI-generated image

    Industrial manufacturing

    Reduce peak demand and support critical production processes with expandable battery capacity.

  • Logistics and distribution centersAI-generated image

    Logistics and distribution centers

    Store rooftop solar electricity, manage EV charging peaks and accommodate growing energy demand without automatically increasing PCS capacity.

  • Cold storage and food processingAI-generated image

    Cold storage and food processing

    Extend backup duration for essential refrigeration loads and reduce demand peaks during normal operation.

  • Mining and remote industrial sitesAI-generated image

    Mining and remote industrial sites

    Combine solar, battery storage and diesel generation to reduce fuel consumption and improve energy availability.

  • Water treatment and pumping stationsAI-generated image

    Water treatment and pumping stations

    Manage large electrical loads and provide extended backup capacity for essential pumping operations.

1/5

Also in the LONGi ONE C&I range

Hi-MO One Mona. Compact all-in-one battery storage for commercial and industrial businesses.

Discuss your energy storage project.

Tell us about your project plans and our regional team can help identify the next step.

We use these details only to reply to your request.

Thank you. Your inquiry has been sent to the regional team.
Something went wrong while sending the form. Please try again.